Network Port Layout
Last updated
Was this helpful?
Last updated
Was this helpful?
The default 1G management port is labeled "L1" and closets to the power supply.
This L1 port can bridge the IPMI/BMC port (single RJ45 connection for both Server and BMC)
The L2 port can not bridge the IPMI/BMC port
The IPMI Port is a dedicated segmented network port used for out of band communication with the system. It allows power on/off and KVM capabilities. Highly recommend connecting this. Default IP address is 192.168.0.93/24
The Management ports are 1G SFP/ 10G SFP+ (Capture System). Or 10G/40G QSFP+ (Analytics systems) These can be run in standard, or link bonded / redundant setup.
FMADIO40Gv3 Capture systems,
Port Count
Port Speed
Interface
2
10G
SFP+
2
1G
SFP
FMADIO40Gv3 Gen3 Analytics Systems
Port Count
Port Speed
Interface
2
40Gbps
QSFP+
4
10Gbps
QSFP+ Breakout Cables
Capture ports can be configured in the following way.
Port Count
Port Speed
Interface
2
100Gbps
QSFP28 (FEC or no FEC)
2
40Gbps
QSFP+
8
25Gbps
QSFP28 (Not released yet)
8
10Gbps
QSFP+ Breakout Cables
The PPS connector is a 1 Pulse Per Second time synchronization cable. It runs on a 3.3V trigger signal the interface is SMA Coaxial cable