--- title: "FMADIO Pro 5414" slug: "fmadio-5414" updated: 2025-08-04T09:39:07Z published: 2025-08-04T09:39:07Z canonical: "docs.fmad.io/fmadio-5414" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.fmad.io/llms.txt > Use this file to discover all available pages before exploring further. # FMADIO Pro 5414 ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/image(181).png?sv=2026-02-06&spr=https&st=2026-11-21T01%3A57%3A13Z&se=2026-11-21T02%3A57%3A13Z&sr=b&sp=r&sig=VCUj0tOFJzSKn0KaeDit0M9afHbfTYqMKALWfSllAl0%3D) FMADIO Generation 4 Pro systems 5414 - | SKU | Description | | --- | --- | | [FMADIO Pro 5414](/v1/docs/fmadio-5214#5214-rear-port-layout) | Standard Model. | | [FMADIO Pro 5414A](/v1/docs/fmadio-5214#5214a-2-x-sfp28-management-ports) | 2 x SFP28 10G/25G management ports | ## Specification ### Capture FMADIO-5414 systems are designed for sustained 100Gbps capture at all packet sizes. With support for micro bursting to 200Gbps | Capture Rate Sustained | 100Gbps to disk | | --- | --- | | | 149.8M packets per second | | Capture rate Burst | 200Gbps micro bursting | | | 299.6M packets per second | | Capture Hardware | Custom inhouse FPGA Design | | | 16GB HBM2e | | Packet Size Capture | Minimum 48 Byte (Captures some RUNT packets) | | | Maximum 9218 Byte | ### Processing This system is build using the 4th Generation AMD EPYC™ Processors for maximum analytics processing of the data | CPU | 96 Cores | | --- | --- | | | 192 Threads | | RAM | 768GB of DDR5 | ### Power The FMADIO-5414 systems features dual 1600W (240V) 80 PLUS Platinum redundant power supplies - System will run on a single PSU without any alert noise | Input | 100-120V~/12A, 50-60Hz | | --- | --- | | | 200-240V~/10A, 50-60Hz | | Output | Max 1600W/200-240V~ or 240Vdc Input | | | + 12V/133A | | | + 12Vsb/2.5A | | Average Power | 600W - 700W | ### Environment | Operating temperature | 10°C - 25°C (50°F - 77°F) | | --- | --- | | Operating humidity | 8% - 80% (non-condensing) | | Non-operating temperature | -40°C to 60°C (-40°C to 140°C) | | Non-operating humidity | 20% - 95% (non-condensing) | ### Cooling | Fan | 12x Hot-Swappable 40mm | | --- | --- | ### Physical Dimensions | Rack Size | 1U Rack-mountable chassis | | --- | --- | | Rails | 787 mm (31") toolless rails | | Width x Height x Depth | 482 mm x 787mm x 44mm (19" x 31" x 1.75") | | Weight | 25.8 kg (56.9 lbs) | ### Shipping Dimensions | Width x Height x Depth | 1046mm x 597mm x 244mm | | --- | --- | | Weight | 27kg | ### Shipping Customs | HS Code | 8471.50.0150 | | --- | --- | | ECCN | 5A992.c | | COO | Taiwan | --- ## FMADIO Pro 5414 Focused on 100Gbps sustained Capture and 100Gbps sustained analytics processing of that data. ### **Front Panel layout** ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/QSFP28 4 x 25 (5).png?sv=2026-02-06&spr=https&st=2026-11-21T01%3A57%3A13Z&se=2026-11-21T02%3A57%3A13Z&sr=b&sp=r&sig=gYvO6CtYSO5ryoJ%2BYKzf3mG21CI5zzjzsxRwYgBWEE4%3D) | ID | Name | Description | Form Factor | | --- | --- | --- | --- | | F1 | USB Port | USB Port | USB A | | F2 | Reset Button | | Pin hole | | F3 | LED | | | | F4 | ID Button | ID Server Locate | Button | | F5 | Power Button | Powers system On / Off | Button | | S0-S11 | SSD Drive bays | SSD Drive bays | | ### Storage Options | **Drive Bay** | **FMADIO-5414-45T** | **FMADIO-5414-90T** | **FMADIO-5414-180T** | **FMADIO-5414-360T** | | --- | --- | --- | --- | --- | | S0 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S1 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S2 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S3 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S4 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S5 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S6 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S7 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S8 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S9 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S10 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S11 | 3.84TB | 7.68TB | 15.6TB | 30TB | ### Rear port layout ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/200Gv4 Port Layouts.drawio (1)(2).png?sv=2026-02-06&spr=https&st=2026-11-21T01%3A57%3A13Z&se=2026-11-21T02%3A57%3A13Z&sr=b&sp=r&sig=%2BGnoU%2FC9em1X15BCU0%2FmxPiq4N8ieytgR3kSCXRe4EY%3D) | ID | Name | Description | Form Factor | Logical Port | | --- | --- | --- | --- | --- | | R1 | Capture Port | Capture Port A | 100Gbps QSFP28 | cap0 | | R2 | Capture Port | Capture Port B | 100Gbps QSFP28 | cap1 | | R3 | Management Port High Speed | Management Port High Speed A | 100Gbps QSFP28 | man10 | | R4 | Management Port High Speed | Management Port High Speed B | 100Gbps QSFP28 | man11 | | R5 | Management Port | Management Port 1G B | 1G RJ45 | man1 | | R6 | Management Port | Management Port 1G A | 1G RJ45 | man0 | | R7 | BMC Port | Out of Band IPMI / BMC Port 1G | 1G RJ45 | bmc0 | | R8 | USB Ports | USB Ports | USB A | | | R9 | Display Port | Mini Display Port | Mini-DP | | | R10 | Power supply | Power Supply 1600W B | C13/C14 Port | psu1 | | R11 | Power supply | Power Supply 1600W A | C13/C14 Port | psu0 | | R12 | BMC Serial Port | RJ45 Serial port (Not Ethernet) | RJ45 Serial | | | R13 | PPS In (TBD) | SMA PPS In (TBD) | SMA | | ### Port Breakouts Capture and management ports R1 thru R4 may be broken out using the appropriate breakout cables. | ID | Name | QSFP28 Breakout | Part number(s) | | --- | --- | --- | --- | | R1-R2 | Capture Ports | 2 × 100G | | | R1-R2 | Capture Ports | 2 × 40G | | | R1-R2 | Capture Ports | 4 × 25G | | | R1-R2 | Capture Ports | 8 × 10G | | | R1-R2 | Capture Ports | 4 × 10G ([Layer 1 Capture Mode](https://docs.fmad.io/docs/features-layer-1-capture-packet-in-packet)) | | | R3-R4 | Management Ports | 2 × 100G | | | R3-R4 | Management Ports | 8 × 25G | | | R3-R4 | Management Ports | 8 × 10G | | --- ## FMADIO Pro 5414A (2x10G or 25G Management Ports) This SKU option changes the default Management interfaces to use SFP/SFP+/SFP28 high-speed management ports that run at 10G/25G port speeds. ### Front Port ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/Front_Disk_small.png?sv=2026-02-06&spr=https&st=2026-11-21T01%3A57%3A13Z&se=2026-11-21T02%3A57%3A13Z&sr=b&sp=r&sig=AbwXggzw3zxrtmWg4XV0lp71pWROBKG9D7dD1uURRcU%3D) ### Rear Port ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/200Gv4 Port Layouts.drawio (2).png?sv=2026-02-06&spr=https&st=2026-11-21T01%3A57%3A13Z&se=2026-11-21T02%3A57%3A13Z&sr=b&sp=r&sig=mRHTzzMUX%2FAuhS44C2D3%2BriYtZ2dd%2FLKtdzX1JPp8H0%3D) | PID | Name | Description | Form Factor | Logical Port | | --- | --- | --- | --- | --- | | R1 | Capture Port | Capture Port A | 100Gbps QSFP28 | cap0 | | R2 | Capture Port | Capture Port B | 100Gbps QSFP28 | cap1 | | R3 | Management Port High Speed | Management Port High Speed A | 10G/25G SFP28 | man10 | | R4 | Management Port High Speed | Management Port High Speed B | 10G/25G SFP28 | man11 | | R5 | Management Port | Management Port 1G B | 1G RJ45 | man1 | | R6 | Management Port | Management Port 1G A | 1G RJ45 | man0 | | R7 | BMC Port | Out of Bands IPMI / BMC Port 1G | 1G RJ45 | bmc0 | | R8 | | USB Ports | USB A | | | R9 | Display Port | Mini Display Port | Mini-DP | | | R10 | Power supply | Power Supply 1600W B | C13/C14 Port | psu1 | | R11 | Power supply | Power Supply 1600W A | C13/C14 Port | psu0 | | R12 | BMC Serial port | BMC Serial Port | RJ45 (not ethernet) | | | R13 | PPS In (TBD) | PPS In (TBD) | SMA | | ### Port Breakouts Capture and management ports R1 thru R4 may be broken out using the appropriate breakout cables. | ID | Name | QSFP28 Breakout | Part number(s) | | --- | --- | --- | --- | | R1-R2 | Capture Ports | 2 × 100G | | | R1-R2 | Capture Ports | 2 × 40G | | | R1-R2 | Capture Ports | 4 × 25G | | | R1-R2 | Capture Ports | 8 × 10G | | | R1-R2 | Capture Ports | 4 × 10G ([Layer 1 Capture Mode](https://docs.fmad.io/docs/features-layer-1-capture-packet-in-packet)) | | | R3-R4 | Management Ports | 2 × 25G | | | R3-R4 | Management Ports | 2 × 10G | | --- ## ##