--- title: "FMADIO Pro 5214" slug: "fmadio-5214" updated: 2026-01-29T06:45:31Z published: 2026-01-29T06:45:31Z canonical: "docs.fmad.io/fmadio-5214" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.fmad.io/llms.txt > Use this file to discover all available pages before exploring further. # FMADIO Pro 5214 ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/FMADIO 2.2 (with reflection)_small.png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=2la310iTCGh%2F%2BAYwS%2FSEc9NtV6bAVGrxH9d4QorYDNU%3D) There are three different models of the FMADIO Pro 5214 | SKU | Description | | --- | --- | | [FMADIO Pro 5214](/v1/docs/fmadio-5214#5214-rear-port-layout) | Standard Model. | | [FMADIO Pro 5214A](/v1/docs/fmadio-5214#5214a-2-x-sfp28-management-ports) | 2 x SFP28 management ports. | | [FMADIO Pro 5214B](https://docs.fmad.io/docs/fmadio-5214#fmadio-pro-5214b-4x10g-or-25g-management-ports) | 4 x SFP28 25G management ports | | [FMADIO Pro 5214](/v1/docs/fmadio-5214#5214a-2-x-sfp28-management-ports)S | Configured with scratch disks as default. | --- ## Specification ### Capture FMADIO-5214 systems are designed for sustained 40Gbps capture at all packet sizes. With support for micro bursting to 80Gbps | Capture Rate Sustained | 40Gbps to disk | | --- | --- | | | 59.8M packets per second | | Capture rate Burst | 80Gbps micro bursting | | | 119.6M packets per second | | Capture Hardware | Custom inhouse FPGA Design | | | 16GB HBM2e | | Packet Size Capture | Minimum 48 Byte (Captures some RUNT packets) | | | Maximum 9218 Byte | ### Processing This system is build using the 4th Generation AMD EPYC™ Processors for maximum analytics processing of the data | CPU | 96 Cores | | --- | --- | | | 192 Threads | | RAM | 768GB of DDR5 | ### Power The FMADIO-5214 systems features dual 1600W (240V) 80 PLUS Platinum redundant power supplies - System will run on a single PSU without any alert noise | Input | 100-120V~/12A, 50-60Hz | | --- | --- | | | 200-240V~/10A, 50-60Hz | | Output | Max 1600W/200-240V~ or 240Vdc Input | | | + 12V/133A | | | + 12Vsb/2.5A | | Average Power | 600W - 700W | ### Environment | Operating temperature | 10°C - 25°C (50°F - 77°F) | | --- | --- | | Operating humidity | 8% - 80% (non-condensing) | | Non-operating temperature | -40°C to 60°C (-40°C to 140°C) | | Non-operating humidity | 20% - 95% (non-condensing) | ### Cooling | Fan | 12x Hot-Swappable 40mm | | --- | --- | ### Physical Dimensions | Rack Size | 1U Rack-mountable chassis | | --- | --- | | Rails | 787 mm (31") toolless rails | | Width x Height x Depth | 482 mm x 787mm x 44mm (19" x 31" x 1.75") | | Weight | 25.8 kg (56.9 lbs) | ### Shipping Dimensions | Width x Height x Depth | 1046mm x 597mm x 244mm | | --- | --- | | Weight | 27kg | ### Shipping Customs | HS Code | 8471.50.0150 | | --- | --- | | ECCN | 5A992.c | | COO | Taiwan | --- ## FMADIO Pro 5214 Focused on 40Gbps sustained Capture and 40Gbps sustained analytics processing of that data. ### **Front Panel layout** ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/QSFP28 4 x 25 (5).png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=djBYC0ytnP4WQzpcwHwWJnJY5%2BX3WB3w1D%2FxuU1Ck6s%3D) | ID | Name | Description | Form Factor | | --- | --- | --- | --- | | F1 | USB Port | USB Port | USB A | | F2 | Reset Button | | Pin hole | | F3 | LED | | | | F4 | ID Button | ID Server Locate | Button | | F5 | Power Button | Powers system On / Off | Button | | S0-S11 | SSD Drive bays | SSD Drive bays | | ### Storage Options | **Drive Bay** | **FMADIO-5214-15T** | **FMADIO-5214-30T** | **FMADIO-5214-60T** | **FMADIO-5214-120T** | | --- | --- | --- | --- | --- | | S0 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S1 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S2 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S3 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S4 | - | - | - | - | | S5 | - | - | - | - | | S6 | - | - | - | - | | S7 | - | - | - | - | | S8 | - | - | - | - | | S9 | - | - | - | - | | S10 | - | - | - | - | | S11 | - | - | - | - | ### Rear port layout ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/200Gv4 Port Layouts.drawio (1).png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=JwKptYBlqkb8vtVj8cpcOBX%2ByXn%2FDXL2n96J%2FHPMfjc%3D) | ID | Name | Description | Form Factor | Logical Port | | --- | --- | --- | --- | --- | | R1 | Capture Port | Capture Port A | 100Gbps QSFP28 | cap0 | | R2 | Capture Port | Capture Port B | 100Gbps QSFP28 | cap1 | | R3 | Management Port High Speed | Management Port High Speed A | 100Gbps QSFP28 | man10 | | R4 | Management Port High Speed | Management Port High Speed B | 100Gbps QSFP28 | man11 | | R5 | Management Port | Management Port 1G B | 1G RJ45 | man1 | | R6 | Management Port | Management Port 1G A | 1G RJ45 | man0 | | R7 | BMC Port | Out of Band IPMI / BMC Port 1G | 1G RJ45 | bmc0 | | R8 | USB Ports | USB Ports | USB A | | | R9 | Display Port | Mini Display Port | Mini-DP | | | R10 | Power supply | Power Supply 1600W B | C13/C14 Port | psu1 | | R11 | Power supply | Power Supply 1600W A | C13/C14 Port | psu0 | | R12 | BMC Serial Port | RJ45 Serial port (Not Ethernet) | RJ45 Serial | | | R13 | PPS In (TBD) | SMA PPS In (TBD) | SMA | | ### Port Breakouts Capture and management ports R1 thru R4 may be broken out using the appropriate breakout cables. | ID | Name | QSFP28 Breakout | Part number(s) | | --- | --- | --- | --- | | R1-R2 | Capture Ports | 2 × 100G | | | R1-R2 | Capture Ports | 2 × 40G | | | R1-R2 | Capture Ports | 4 × 25G | | | R1-R2 | Capture Ports | 8 × 10G | | | R1-R2 | Capture Ports | 4 × 10G ([Layer 1 Capture Mode](https://docs.fmad.io/docs/features-layer-1-capture-packet-in-packet)) | | | R3-R4 | Management Ports | 2 × 100G | | | R3-R4 | Management Ports | 8 × 25G | | | R3-R4 | Management Ports | 8 × 10G | | --- ## FMADIO Pro 5214A (2x10G or 25G Management Ports) This SKU option changes the default Management interfaces to use SFP/SFP+/SFP28 high-speed management ports that run at 10G/25G port speeds. ### Front Port ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/Front_Disk_small.png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=uEbCIYsuXXpUhRqz2bcugH10Yn7xSl9P%2B0RtznOhMuY%3D) ### Rear Port ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/200Gv4 Port Layouts.drawio (2)(1).png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=SkAXmNmoDFBkYtrNukWV%2B9IqX1UbsivPGvkd4k98VeI%3D) | PID | Name | Description | Form Factor | Logical Port | | --- | --- | --- | --- | --- | | R1 | Capture Port | Capture Port A | 100Gbps QSFP28 | cap0 | | R2 | Capture Port | Capture Port B | 100Gbps QSFP28 | cap1 | | R3 | Management Port High Speed | Management Port High Speed A | 10G/25G SFP28 | man10 | | R4 | Management Port High Speed | Management Port High Speed B | 10G/25G SFP28 | man11 | | R5 | Management Port | Management Port 1G B | 1G RJ45 | man1 | | R6 | Management Port | Management Port 1G A | 1G RJ45 | man0 | | R7 | BMC Port | Out of Bands IPMI / BMC Port 1G | 1G RJ45 | bmc0 | | R8 | | USB Ports | USB A | | | R9 | Display Port | Mini Display Port | Mini-DP | | | R10 | Power supply | Power Supply 1600W B | C13/C14 Port | psu1 | | R11 | Power supply | Power Supply 1600W A | C13/C14 Port | psu0 | | R12 | BMC Serial port | BMC Serial Port | RJ45 (not ethernet) | | | R13 | PPS In (TBD) | PPS In (TBD) | SMA | | ### Storage Options | **Drive Bay** | **FMADIO-5214A-15T** | **FMADIO-5214A-30T** | **FMADIO-5214A-60T** | **FMADIO-5214A-120T** | | --- | --- | --- | --- | --- | | S0 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S1 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S2 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S3 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S4 | - | - | - | - | | S5 | - | - | - | - | | S6 | - | - | - | - | | S7 | - | - | - | - | | S8 | - | - | - | - | | S9 | - | - | - | - | | S10 | - | - | - | - | | S11 | - | - | - | - | ### Port Breakouts Capture and management ports R1 thru R4 may be broken out using the appropriate breakout cables. | ID | Name | QSFP28 Breakout | Part number(s) | | --- | --- | --- | --- | | R1-R2 | Capture Ports | 2 × 100G | | | R1-R2 | Capture Ports | 2 × 40G | | | R1-R2 | Capture Ports | 4 × 25G | | | R1-R2 | Capture Ports | 8 × 10G | | | R1-R2 | Capture Ports | 4 × 10G ([Layer 1 Capture Mode](https://docs.fmad.io/docs/features-layer-1-capture-packet-in-packet)) | | | R3-R4 | Management Ports | 2 × 10G | | | R3-R4 | Management Ports | 2 × 25G | | --- ## FMADIO Pro 5214B (4x10G or 25G Management Ports) This SKU option changes the default Management interfaces to use SFP/SFP+/SFP28 high-speed management ports that run at 10G/25G port speeds. ### Front Port ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/Front_Disk_small.png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=uEbCIYsuXXpUhRqz2bcugH10Yn7xSl9P%2B0RtznOhMuY%3D) ### Rear Port ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/200Gv4 Port Layouts.drawio (1)(4).png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=AoYM4PRsQmhGRIA3FDuh6eMugAmDbaZyZlcrekJP4Uc%3D) | PID | Name | Description | Form Factor | Logical Port | | | | | | --- | --- | --- | --- | --- | --- | --- | --- | --- | | R1 | Capture Port | Capture Port A | 100Gbps QSFP28 | cap0 | | | | | | R2 | Capture Port | Capture Port B | 100Gbps QSFP28 | cap1 | | | | | | R3 | Management Port High Speed | Management Port High Speed A | 10G/25G SFP28 | man10 | | | | | | R4 | Management Port High Speed | Management Port High Speed B | 10G/25G SFP28 | man11 | | | | | | R5 | Management Port High Speed | Management Port High Speed C | 10G/25G SFP28 | man12 | | | | | | R6 | Management Port High Speed | Management Port High Speed D | 10G/25G SFP28 | man13 | | | | | | R7 | Management Port | Management Port 1G B | 1G RJ45 | man1 | | | | | | R8 | Management Port | Management Port 1G A | 1G RJ45 | man0 | | | | | | R9 | BMC Port | Out of Bands IPMI / BMC Port 1G | 1G RJ45 | bmc0 | | | | | | R10 | Power supply | Power Supply 1600W B | C13/C14 Port | psu1 | | | | | | R11 | Power supply | Power Supply 1600W A | C13/C14 Port | psu0 | | | | | | R12 | | USB Ports | USB A | | | | | | | R13 | Display Port | Mini Display Port | Mini-DP | | | | | | | R14 | BMC Serial port | BMC Serial Port | RJ45 (not ethernet) | | | | | | | R15 | PPS In (TBD) | PPS In (TBD) | SMA | | | | | | ### Storage Options | **Drive Bay** | **FMADIO-5214A-15T** | **FMADIO-5214A-30T** | **FMADIO-5214A-60T** | **FMADIO-5214A-120T** | | --- | --- | --- | --- | --- | | S0 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S1 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S2 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S3 | 3.84TB | 7.68TB | 15.6TB | 30TB | | S4 | - | - | - | - | | S5 | - | - | - | - | | S6 | - | - | - | - | | S7 | - | - | - | - | | S8 | - | - | - | - | | S9 | - | - | - | - | | S10 | - | - | - | - | | S11 | - | - | - | - | ### Port Breakouts Capture and management ports R1 thru R4 may be broken out using the appropriate breakout cables. | ID | Name | QSFP28 Breakout | Part number(s) | | --- | --- | --- | --- | | R1-R2 | Capture Ports | 2 × 100G | | | R1-R2 | Capture Ports | 2 × 40G | | | R1-R2 | Capture Ports | 4 × 25G | | | R1-R2 | Capture Ports | 8 × 10G | | | R1-R2 | Capture Ports | 4 × 10G ([Layer 1 Capture Mode](https://docs.fmad.io/docs/features-layer-1-capture-packet-in-packet)) | | | R3-R4 | Management Ports | 2 × 10G | | | R3-R4 | Management Ports | 2 × 25G | | --- ## FMADIO Pro 5214S (Scratch Disks) This SKU focus on having a larger total number of disks as it provides more options for partitioning between Capture Disk / Scratch Disk / Container Disks. ### Front Panel ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/Front_Disk_small.png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=uEbCIYsuXXpUhRqz2bcugH10Yn7xSl9P%2B0RtznOhMuY%3D) ### Rear Panel ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/200Gv4 Port Layouts.drawio (1)(1).png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=tfdjObApy6SgmNfonndbFec5kM1dFvAnRuT9XytwlgI%3D) | PID | Name | Description | Form Factor | Logical Port | | --- | --- | --- | --- | --- | | R1 | Capture Port | Capture Port A | 100Gbps QSFP28 | cap0 | | R2 | Capture Port | Capture Port B | 100Gbps QSFP28 | cap1 | | R3 | Management Port High Speed | Management Port High Speed A | 10G/25G SFP28 | man10 | | R4 | Management Port High Speed | Management Port High Speed B | 10G/25G SFP28 | man11 | | R5 | Management Port | Management Port 1G B | 1G RJ45 | man1 | | R6 | Management Port | Management Port 1G A | 1G RJ45 | man0 | | R7 | BMC Port | Out of Bands IPMI / BMC Port 1G | 1G RJ45 | bmc0 | | R8 | | USB Ports | USB A | | | R9 | Display Port | Mini Display Port | Mini-DP | | | R10 | Power supply | Power Supply 1600W B | C13/C14 Port | psu1 | | R11 | Power supply | Power Supply 1600W A | C13/C14 Port | psu0 | | R12 | BMC Serial port | BMC Serial Port | RJ45 (not ethernet) | | | R13 | PPS In (TBD) | PPS In (TBD) | SMA | | ### Storage Options | **Drive Bay** | **FMADIO-5214S-60T** | | | | | --- | --- | --- | --- | --- | | S0 | 7.6TB | - | - | - | | S1 | 7.6TB | - | - | - | | S2 | 7.6TB | - | - | - | | S3 | 7.6TB | - | - | - | | S4 | 7.6TB | - | - | - | | S5 | 7.6TB | - | - | - | | S6 | 7.6TB | - | - | - | | S7 | 7.6TB | - | - | - | | S8 | - | - | - | - | | S9 | - | - | - | - | | S10 | - | - | - | - | | S11 | - | - | - | - | ### Port Breakouts Capture and management ports R1 thru R4 may be broken out using the appropriate breakout cables. | ID | Name | QSFP28 Breakout | Part number(s) | | --- | --- | --- | --- | | R1-R2 | Capture Ports | 2 × 100G | | | R1-R2 | Capture Ports | 2 × 40G | | | R1-R2 | Capture Ports | 4 × 25G | | | R1-R2 | Capture Ports | 8 × 10G | | | R1-R2 | Capture Ports | 4 × 10G ([Layer 1 Capture Mode](https://docs.fmad.io/docs/features-layer-1-capture-packet-in-packet)) | | | R3-R4 | Management Ports | 2 × 100G | | | R3-R4 | Management Ports | 8 × 25G | | | R3-R4 | Management Ports | 8 × 10G | | --- ## Capture Port Configuration FMADIO system can be configured in multiple difference port configuration modes: | Port Mode | QSFP28 Port 0 (R1) | QSFP28 Port 1 (R2) | | --- | --- | --- | | 2× 100G | cap0 | cap1 | | 2× 40G | cap0 | cap1 | | 4 × 25G | cap0 cap1 cap2 cap3 | Not Connected | | 8 × 10G | cap0 cap1 cap2 cap3 | cap4 cap5 cap6 cap7 | ### 4x25G Port Mode Port mode 4 × 25G is slightly different as its symmetrical. Below is a diagram of the configuration. Note only one QSFP28 port is connected with all 4 cap0, cap1, cap2, cap3 ports are connected to the same QSFP28 transceiver. Do make note QSFP28 Port 0 is the port on the right hand side, highlighted below: ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/image(53).png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=rPZxa9HsCKSjtOhJjSVg%2Fyb9fLQq2mBxWC7rCwVw94w%3D) ![](https://cdn.document360.io/b9aab0c4-36d0-4616-9673-30b661455571/Images/Documentation/image(54).png?sv=2026-02-06&spr=https&st=2026-11-21T02%3A07%3A13Z&se=2026-11-21T03%3A07%3A13Z&sr=b&sp=r&sig=r9YNPi88xO9%2Fg1maH7NoZFzGWpB2xDMxSlS3rl0nPoA%3D) Scratch Disks are helpful for keeping temporary or persistant data outside of the FMADIO host capture system. Many times the OS disks are unable to be used due to capacity or location.