The FMADIO 3514 Lite system is designed for 200Gbps sustained capture rates with light post processing capabilities.
Specification
Capture
FMADIO-3514 systems are designed for sustained 200Gbps capture at all packet sizes.
Capture Rate Sustained | 200Gbps to disk |
298M packets per second | |
Capture rate Burst | 200Gbps micro bursting |
298M packets per second | |
Capture Hardware | Custom inhouse FPGA Design |
16GB HBM2e |
Processing
This system is build using the 4th Generation AMD EPYCâ„¢ Processors for maximum analytics processing of the data
CPU | 64 Cores |
96 Threads | |
RAM | 192GB of DDR5 |
Power
The FMADIO-5214 systems features dual 1600W (240V) 80 PLUS Platinum redundant power supplies
System will run on a single PSU without any alert noise
Input | 100-120V~/12A, 50-60Hz |
200-240V~/10A, 50-60Hz | |
Output | Max 1600W/200-240V~ or 240Vdc Input |
+ 12V/133A | |
+ 12Vsb/2.5A |
Environment
Operating temperature | 10°C - 25°C (50°F - 77°F) |
Operating humidity | 8% - 80% (non-condensing) |
Non-operating temperature | -40°C to 60°C (-40°C to 140°C) |
Non-operating humidity | 20% - 95% (non-condensing) |
Cooling
Fan | 12x Hot-Swappable 40mm |
Physical Dimensions
Rack Size | 1U Rack-mountable chassis |
Rails | 787 mm (31") toolless rails |
Width x Height x Depth | 482 mm x 787mm x 44mm (19" x 31" x 1.75") |
Weight | 25.8 kg (56.9 lbs) |
Shipping Dimensions
Width x Height x Depth | 1046mm x 597mm x 244mm |
Weight | 27kg |
Shipping Customs
HS Code | 8471.50.0150 |
ECCN | 5A992.c |
COO | Taiwan |
FMADIO Pro 3514
This SKU option uses an SFP/SFP+/SFP28 10G/25G Management ports that run while the capture interfaces are QSFP28 10G/25G/40G/100G
Front Port
Rear Port
PID | Name | Description | Form Factor | Logical Port |
---|---|---|---|---|
R1 | Capture Port | Capture Port A | 100Gbps QSFP28 | cap0 |
R2 | Capture Port | Capture Port B | 100Gbps QSFP28 | cap1 |
R3 | Management Port High Speed | Management Port High Speed A | 10G/25G SFP28 | man10 |
R4 | Management Port High Speed | Management Port High Speed B | 10G/25G SFP28 | man11 |
R5 | Management Port | Management Port 1G B | 1G RJ45 | man1 |
R6 | Management Port | Management Port 1G A | 1G RJ45 | man0 |
R7 | BMC Port | Out of Bands IPMI / BMC Port 1G | 1G RJ45 | bmc0 |
R8 | USB Ports | USB A | ||
R9 | Display Port | Mini Display Port | Mini-DP | |
R10 | Power supply | Power Supply 1600W B | C13/C14 Port | psu1 |
R11 | Power supply | Power Supply 1600W A | C13/C14 Port | psu0 |
R12 | BMC Serial port | BMC Serial Port | RJ45 Serial | |
R13 | PPS In (TBD) | PPS In (TBD) | SMA |
Port Breakouts
Capture and management ports R1 thru R4 may be broken out using the appropriate breakout cables.
ID | Name | QSFP28 Breakout | Part number(s) |
---|---|---|---|
R1-R2 | Capture Ports | 2 × 100G | |
R1-R2 | Capture Ports | 2 × 40G | |
R1-R2 | Capture Ports | 4 × 25G | |
R1-R2 | Capture Ports | 8 × 10G | |
R1-R2 | Capture Ports | 4 × 10G (Layer 1 Capture Mode) | |
R3-R4 | Management Ports | 2 × 10G | |
R3-R4 | Management Ports | 2 × 25G |